Intramedullary osteosynthesis of complex proximal femoral fractures with the Targon PF nail.

Journal: Injury
Published:
Abstract

We evaluated the performance of the Targon PF nailing system in the treatment of complex proximal femoral fractures with a retrospective analysis of prospectively collected data for 94 patients with a complex proximal femoral fracture (subtrochanteric fracture or fracture with reversed fracture line pattern) treated with a Targon PF nail. There were no intra-operative femoral fractures. Late complications requiring reoperation were one femoral fracture and one fracture around the nail secondary to tumour. Seven nails had to be dynamised and a further six 'self-dynamised' at the site of the distal locking screw. One patient required revision of the distal locking. Only one other patient required secondary surgery for a wound haematoma. There were no cases of implant cut-out or non-union. The Targon PF nail represents a progressive development in the design of intramedullary nails for proximal femoral fractures and the results compare favourably with other intramedullary systems used to treat complex proximal femoral fractures.

Authors
G Heinert, M Parker