Renal function after implantation of continuous versus pulsatile flow left ventricular assist devices.

Journal: The Journal Of Heart And Lung Transplantation : The Official Publication Of The International Society For Heart Transplantation
Published:
Abstract

Background: This study was designed to determine the effect of continuous vs pulsatile flow devices on renal function after left ventricular assist device (LVAD) implantation.

Methods: Ninety-two patients undergoing LVAD implantation as bridge-to-transplant therapy were retrospectively analyzed. Patients receiving continuous flow devices (n = 63, 68.5%) were compared with patients receiving pulsatile flow devices (n = 29, 31.5%). Renal function was assessed by 2 calculated glomerular filtration rates (GFR) using the Modification of Diet in Renal Disease (MDRD)-derived GFR (ml/min/1.73 m(2)) and the Cockcroft-Gault-derived creatinine clearance (CrCl, ml/min).

Results: Mean GFR/CrCl was comparable between the groups at LVAD implantation, in the post-implantation period, and at transplantation. Both groups had a significant increase in mean GFR at Week 1 post-implantation (continuous, 59.4 +/- 22.8 to 76.4 +/- 38.6, p = 0.001; pulsatile, 52.5 +/- 21.1 to 69.2 +/- 34.7; p = 0.007), Week 4 (continuous, 59.9 +/- 23.0 to 84.3 +/- 32.9; p < 0.001; pulsatile, 50.3 +/- 21.1 to 79.9 +/- 38.7, p = 0.007), and Week 12 (continuous, 60.3 +/- 23.1 to 75.3 +/- 30.2, p = 0.004; pulsatile, 55.5 +/- 23.1 to 74.2 +/- 27.2, p = 0.037) that was also seen with the Cockcroft-Gault-calculated CrCl. No significant increase occurred in mean GFR/CrCl to transplantation. Incidence of post-implantation renal failure was comparable between the groups (continuous, 38.1%; pulsatile, 31.0%; p = 0.512).

Conclusions: After LVAD implantation, patients with continuous flow devices and patients with pulsatile flow devices have comparable renal function.

Authors
Sigrid Sandner, Daniel Zimpfer, Philipp Zrunek, Daniela Dunkler, Heinrich Schima, Angela Rajek, Michael Grimm, Ernst Wolner, Georg Wieselthaler
Relevant Conditions

Heart Failure