Adequacy of glycemic control in hemodialysis patients with diabetes.
Objective: We sought to measure the prevalence of inadequate glycemic control in prevalent hemodialysis patients with diabetes and to examine independent predictors of inadequate glycemic control in these patients.
Methods: This is a cross-sectional study of prevalent hemodialysis patients with diabetes in southeastern Ontario (n = 100). Data were collected by chart review and interview. The outcome variable was inadequate glycemic control defined as HbA1c (A1C) >0.07. Other measured variables were diabetes type, diabetes duration, diabetes physician, blood glucose monitoring, diabetes medications, BMI, time on dialysis, and other demographic, clinical, and laboratory variables.
Results: Fifty-four patients had A1C >0.07. In bivariate analysis, these patients had a longer diabetes duration (23.6 vs. 14.7 years, P < 0.001), higher proportion with insulin use (81.5 vs. 58.7%, P = 0.012), higher proportion with microvascular complications (66.7 vs. 43.5%, P = 0.017), and lower erythropoietin (EPO) dose (7.0 vs. 11.9 x 10(3) units/week, P < 0.01) than patients with adequate glycemic control. There was no difference between the two groups in terms of macrovascular complications (59.3 vs. 65.2%, P = 0.54). In multiple logistic regression controlling for age and diabetes type, the diabetes duration (odds ratio 1.09 [95% CI 1.04-1.15], P < 0.001), EPO dose (0.90 [0.85-0.97], P < 0.01), and blood glucose monitoring (10.06 [1.03-98.74], P = 0.05) were the only significant independent predictors of A1C >0.07.
Conclusions: A high proportion of hemodialysis patients with diabetes had inadequate glycemic control, particularly those with longstanding disease. Patients with inadequate glycemic control had a significantly higher burden of microvascular complications.