Significance of tilt table testing in patients with suspected arrhythmic syncope and negative electrophysiologic study.

Journal: Journal Of Cardiovascular Electrophysiology
Published:
Abstract

Background: The diagnostic significance of a tilt table test (TTT) in patients with a suspected arrhythmic etiology for syncope and negative electrophysiologic study (EPS) has not been previously assessed comparing the TTT results with the findings of prolonged monitoring using an implantable loop recorder (ILR). We sought to assess the diagnostic yielding of TTT in patients with suspected arrhythmic syncope and negative EPS.

Results: In 81 patients with suspected arrhythmic etiology for syncope and negative EPS, TTT was performed and an ILR implanted regardless the results of TTT. TTT was positive in 38 patients. During follow-up, syncope or presyncope recurred in 32 patients (39.5%). No differences were found in recurrence rates in patients with positive and negative TTT (31.5% vs 46.5%, P = ns). According to rhythm registered during ILR activation, mechanisms of syncopal events were classified as: arrhythmic (atrioventricular [AV] block and ventricular tachycardia; n = 18), neurally mediated (sinus bradycardia and sinus pause; n = 9), and indeterminate (normal sinus rhythm; n = 5). There was no statistical association between the results of TTT and the mechanism of syncope.

Conclusions: In patients with a suspected arrhythmic etiology for syncope and a negative EPS, TTT is of little value to predict the mechanism of syncope and the ILR implantation seems to be a useful and safe diagnostic strategy.

Authors
Roberto García Civera, Ricardo Ruiz Granell, Salvador Morell Cabedo, Rafael Sanjuan Mañez, Angel Ferrero, Angel Martínez Brotons, Araceli Roselló, Segismundo Botella, Angel Llacer
Relevant Conditions

Fainting, Hyperventilation