Frequency of atrial tachyarrhythmias following transcatheter closure of patent foramen ovale.

Journal: The Journal Of Invasive Cardiology
Published:
Abstract

Background: Transcatheter closure of patent foramen ovale (PFO) in patients with a history of cryptogenic stroke is performed with increasing frequency. However, the long-term effects of these closure devices on atrial tachyarrhythmias (ATs) are not known.

Results: The study population included 71 patients [31 (44%) men, aged 54 +/- 14 years] with PFO, diagnosed by transesophageal echocardiography (TEE), and greater than or equal to 1 cryptogenic stroke (n = 70) or orthodoxia (n = 1). Patients underwent transcatheter closure of PFO using a 28 mm (n = 53) or a 33 mm (n = 18) CardioSEAL closure device (n = 67) or an Amplatzer occluder (n = 4). Five (7%) patients presented with newly diagnosed (n = 4) or recurrent (n = 1) episodes of AT (3 atrial fibrillation and 2 typical atrial flutter) within 1 to 480 days following the procedure, with an average time to onset of 175 +/- 221 days. ATs were more frequent in those who received a 33 mm device than those who received a 28 mm device [4/18 (22%) vs. 1/53 (2%); p < 0.05]. Patients with ATs showed a trend toward a larger left atrium only on apical view (6.5 +/- 1.4 cm vs. 5.1 +/- 0.9 cm; p = 0.05). However, the difference in left atrial size on parasternal view and right atrial size between the 2 groups was not statistically significant (4.5 +/- 1.1 cm vs. 3.7 +/- 0.8 cm and 5.9 +/- 2.4 cm vs. 4.6 +/- 0.7 cm). Conclusion. Compared to the age-matched population, sustained ATs appear to be relatively common following transcatheter closure of PFO. In our series, they seemed to occur more frequently in patients who received larger devices.

Authors
Jamshid Alaeddini, Georges Feghali, Stephen Jenkins, Stephen Ramee, Christopher White, Freddy Abi Samra