Background: The incidence of colorectal cancer (CRC) has been increasing. We evaluated uptake rates and outcomes of faecal immunochemical test (FIT) and Guaiac test (gFOBT) kits as part of a two-step CRC screening.

Methods: A 3-year CRC screening program for a defined population of construction workers was conducted. Those satisfying the inclusion criteria were provided with gFOBT or FIT kits. Individuals testing positive were invited for a colonoscopy.

Results: A total of 909 faecal testing kits were distributed. Age range was 53-60 years. Compliance rate was higher for FIT (58.3%) as compared to gFOBT (46.7%) (p = 0.0006). FIT detected adenomatous polyps and CRC in 37.5 and 25%, respectively, whereas; gFOBT detected 23.5 and 18%. Colonoscopies were normal in 53 and 25% tested positive by gFOBT and FIT, respectively (p = 0.016).

Conclusions: The FIT was more cost-effective when compared with gFOBT with higher return rate, sensitivity and specificity. A comparative study of faecal occult blood kits in a CRC screening program in a healthy cohort of construction workers.