Lumbar pedicle screw placement: Using only AP plane imaging.
Background: Variations in the pedicle morphology and presence of spinal deformities can make pedicle screw placement challenging. Recently, computerized tomography (CT) guided screw placement has reportedly improved the surgical accuracy of pedicle screw insertion. However, it is time consuming and expensive. We combined single-plane fluoroscopy in AP projection alone with tactile guidance for placing pedicle screws more efficiently and accurately. This report presents our results with this technique.
Methods: An Institutional Review Board (IRB) approved retrospective study was carried out on 308 patients who underwent lumbar spinal fusion with 1806 pedicle screws placed using fluoroscopy only in the AP plane. There were 182 patients with two-level fusion, 79 with single-level fusion, 26 with three-level fusion, and 21 with more than three-level fusions. The indications of surgery included spondylolisthesis, adult scoliosis, revision surgery, lumbar canal stenosis, and discogenic pain. Pedicle screws were inserted under fluoroscopic guidance in the AP plane alone with a final lateral image after completion of implant placement. Radiographs were performed postoperatively in all patients and CT scans were obtained on 78 patients with 588 screws.
Results: Twenty nine (5%) cortical wall perforations were noted amongst the 588 screws that were evaluated with a CT scan and did not result in postoperative vascular or neural complications. Anterior cortical vertebral violation was noted in 14 patients, while in 9 patients the screws penetrated the lateral wall of the pedicle. The medial wall of the pedicle was encroached in six patients with no frank perforations.
Conclusions: Placement of pedicle screws under fluoroscopic guidance using AP plane imaging alone with tactile guidance is safe, fast, and reliable. However, a good understanding of the radiographic landmarks is a prerequisite.