Simultaneous determination of uric Acid and xanthine using a poly(methylene blue) and electrochemically reduced graphene oxide composite film modified electrode.

Journal: Journal Of Analytical Methods In Chemistry
Published:
Abstract

Poly(methylene blue) and electrochemically reduced graphene oxide composite film modified electrode (PMB-ERGO/GCE) was successfully fabricated by electropolymerization and was used for simultaneous determination of uric acid (UA) and xanthine (Xa). Based on the excellent electrocatalytic activity of PMB-ERGO/GCE, the electrochemical behaviors of UA and Xa were studied by cyclic voltammetry (CV) and square wave voltammetry (SWV). Two anodic sensitive peaks at 0.630 V (versus Ag/AgCl) for UA and 1.006 V (versus Ag/AgCl) for Xa were given by CV in pH 3.0 phosphate buffer. The calibration curves for UA and Xa were obtained in the range of 8.00 × 10(-8)~4.00 × 10(-4) M and 1.00 × 10(-7)~4.00 × 10(-4) M, respectively, by SWV. The detection limits for UA and Xa were 3.00 × 10(-8) M and 5.00 × 10(-8) M, respectively. Finally, the proposed method was applied to simultaneously determine UA and Xa in human urine with good selectivity and high sensitivity.

Authors
Gen Liu, Wei Ma, Yan Luo, Deng-ming Sun, Shuang Shao