Influences of the inner retinal sublayers and analytical areas in macular scans by spectral-domain OCT on the diagnostic ability of early glaucoma.
Objective: We investigated the influences of the inner retinal sublayers and analytical areas in macular scans by spectral-domain optical coherence tomography (OCT) on the diagnostic ability of early glaucoma.
Methods: A total of 64 early (including 24 preperimetric) glaucomatous and 40 normal eyes underwent macular and peripapillary retinal nerve fiber layer (pRNFL) scans (3D-OCT-2000). The area under the receiver operating characteristics (AUC) for glaucoma diagnosis was determined from the average thickness of the total 100 grids (6 × 6 mm), central 44 grids (3.6 × 4.8 mm), and peripheral 56 grids (outside of the 44 grids), and for each macular sublayer: macular RNFL (mRNFL), ganglion cell layer plus inner plexiform layer (GCL/IPL), and mRNFL plus GCL/IPL (ganglion cell complex [GCC]). Correlation of OCT parameters with visual field parameters was evaluated by Spearman's rank correlation coefficients (rs).
Results: The GCC-related parameters had a significantly larger AUC (0.82-0.97) than GCL/IPL (0.81-0.91), mRNFL-related parameters (0.72-0.94), or average pRNFL (0.88) in more than half of all comparisons. The central 44 grids had a significantly lower AUC than other analytical areas in GCC and mRNFL thickness. Conversely, the peripheral 56 grids had a significantly lower AUC than the 100 grids in GCL/IPL inferior thickness. Inferior thickness of GCC (rs, 0.45-0.49) and mRNFL (rs, 0.43-0.51) showed comparably high correlations with central visual field parameters to average pRNFL thickness (rs, 0.41, 0.47) even in the central 44 grids.
Conclusions: The diagnostic ability of macular OCT parameters for early glaucoma differed by inner retinal sublayers and also by the analytical areas studied.