Single screw-rod anterior instrumentation for thoracolumbar burst fractures with incomplete neurological deficit.

Journal: Journal Of Orthopaedic Surgery (Hong Kong)
Published:
Abstract

Objective: To evaluate the outcome of single screwrod anterior instrumentation for thoracolumbar burst fractures with incomplete neurological deficit.

Methods: 16 men and 5 women aged 22 to 55 (mean, 34) years underwent single screw-rod anterior instrumentation for thoracolumbar burst fractures with incomplete neurological deficit. The vertebrae involved were T10 (n=2), T11 (n=2), T12 (n=7), L1 (n=8), and L2 (n=2). No patient had disruption of the posterior ligament complex. Postoperatively, a thoracolumbar sacral orthosis was used until solid fusion. Outcome measures included neurological recovery, degree of kyphosis, complications, and pain and functional status of the patients.

Results: The mean follow-up duration was 36 (range, 13-50) months. All patients recovered neurologically by at least one grade. Of the 21 patients, 6 improved from grade B to grade C (n=4) or grade D (n=2), 13 from grade C to grade D, and 2 from grade D to grade E. The mean degree of kyphosis improved from 23º ± 5º to 7º ± 3º. Seven patients had complications including ipsilateral basal atelectasis (n=3), urinary tract infection (n=1), haematuria (n=1), postoperative ileus (n=1), and superficial wound infection (n=1). None had iatrogenic visceral or vascular injury, pseudoarthrosis or hardware-related complications. Only one patient had severe back pain persistently.

Conclusions: Single screw-rod anterior instrumentation supplemented with an orthosis can be an alternative for double screw-rod anterior instrumentation for thoracolumbar burst fractures in patients with smaller vertebral bodies.

Authors
Siddhartha Sharma, Dara Singh, Manjeet Singh, Arvind Kohli, Gurjit Singh, Mohit Arora
Relevant Conditions

Kyphosis, Fractured Spine