Diagnostic accuracy of endoscopic ultrasound-guided fine-needle aspiration for pancreatic cancer: a meta-analysis.

Journal: Pancreatology : Official Journal Of The International Association Of Pancreatology (IAP) ... [Et Al.]
Published:
Abstract

Objective: EUS-FNA of pancreatic lesion has been put into clinical use widely in many centers. The present meta-analysis was conducted to study the diagnostic role of EUS-FNA in pancreatic cancer.

Methods: A comprehensive review of study on the precision of EUS-FNA in the diagnosis of pancreatic cancer. A random effects model was used to pool the sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR) and diagnostic odds ratio (DOR). A summary receiver-operating characteristic (SROC) was constructed to summarize the overall test performance.

Results: Thirty-one articles were eligible for the meta-analysis. The pooled sensitivity, specificity, PLR, NLR and DOR of EUS-FNA in the diagnosis of pancreatic cancer were 0.89 (95% CI: 0.88-0.90), 0.96 (95% CI: 0.95-0.97), 16.88 (95% CI: 10.63-26.79), 0.13 (95%CI: 0.10-0.16) and 150.80 (95%CI: 95.94-237.03) respectively. In subgroup meta-analysis of the prospective studies, the pooled sensitivity, specificity, PLR, NLR and DOR were 0.91 (95% CI: 0.90-0.93), 0.94 (95% CI: 0.91-0.96), 11.19 (95% CI: 6.36-19.69), 0.10 (95% CI: 0.07-0.15) and 125.22 (62.37-251.41). The area under the curve (AUC) was 0.97, indicating a good performance of overall accuracy.

Conclusions: EUS-FNA has the high sensitivity and specificity in differentiating pancreatic cancer. Moreover, it is also a safe diagnostic modality with little complications.

Relevant Conditions

Pancreatic Cancer