Treatment of breast cancer with simultaneous integrated boost in hybrid plan technique : Influence of flattening filter-free beams.
Objective: The present study compares in silico treatment plans using hybrid plan technique during hypofractionated radiation of mammary carcinoma with simultaneous integrated boost (SIB). The influence of 6 MV photon radiation in flattening filter free (FFF) mode against the clinical standard flattening filter (FF) mode is to be examined.
Methods: RT planning took place with FF and FFF radiation plans for 10 left-sided breast cancer patients. Hybrid plans were realised with two tangential IMRT fields and one VMAT field. The dose prescription was in line with the guidelines in the ARO-2010-01 study. The dosimetric verification took place with a manufacturer-independent measurement system.
Results: Required dose prescriptions for the planning target volumes (PTV) were achieved for both groups. The average dose values of the ipsi- and contralateral lung and the heart did not differ significantly. The overall average incidental dose to the left anterior descending artery (LAD) of 8.24 ± 3.9 Gy in the FFF group and 9.05 ± 3.7 Gy in the FF group (p < 0.05) were found. The dosimetric verifications corresponded to the clinical requirements. FFF-based RT plans reduced the average treatment time by 17 s/fraction.
Conclusions: In comparison to the FF-based hybrid plan technique the FFF mode allows further reduction of the average LAD dose for comparable target volume coverage without adverse low-dose exposure of contralateral structures. The combination of hybrid plan technique and 6 MV photon radiation in the FFF mode is suitable for use with hypofractionated dose schemes. The increased dose rate allows a substantial reduction of treatment time and thus beneficial application of the deep inspiration breath hold technique.