The use of a cutting balloon in contemporary reverse controlled antegrade and retrograde subintimal tracking (reverse CART) technique.
Journal: Cardiovascular Intervention And Therapeutics
Published:
Abstract
The key concept of reverse controlled antegrade and retrograde tracking (CART) technique is retrograde puncture with a tapered wire to an antegrade balloon (contemporary reverse CART) or new connections between the antegrade and retrograde subintimal space (classical reverse CART). In our case, a 75-year-old man with severe chronic total occlusion of the right coronary artery, reverse CART with conventional balloons could not be accomplished. Externalization wiring was completed by contemporary reverse CART using a cutting balloon as an antegrade balloon to improve the fenestration force of the retrograde guidewire. Thus, the use of a cutting balloon for contemporary reverse CART might be promising.
Relevant Conditions