The reliability of a smartphone goniometer application compared with a traditional goniometer for measuring first metatarsophalangeal joint dorsiflexion.
Background: Adequate sagittal plane motion of the first metatarsalphalangeal joint (1st MTPJ) is important during normal gait and goniometric measurement is commonly used as a diagnostic and outcome assessment tool. We aimed to determine the intra and inter-rater reliability together with the concurrent validity of a universal plastic goniometer (UG) and a smartphone applicationlication (Dr G) for the measurement of dorsiflexion at the 1st MTPJ.
Methods: Measurement of joint position and passive range of motion of the 1st MTPJ dorsiflexion was compared using a UG and DrG goniometer. A double-blind repeated measures design was utilized, with intraclass correlation coefficient (ICC) used to determine levels of reliability.
Results: For joint position good intra-rater reliability (ICC >0.861) and good inter-rater reliability (ICC >0.823) was noted. However, the Dr G application consistently measured lower angles (mean 27.8° (SD 8.37)) than the UG (mean 32° (SD 11.7)) and these associations were significant (r = 0.399, p < 0.001). For passive range of motion, the mean total range of dorsiflexion motion (from maximum plantarflexed position to maximum dorsiflexed position) was 82.8° (SD 12.2) for the UG and 82.9° (SD 11.3) for the Dr G application. Both instruments demonstrated high levels of intra-rater reliability (ICC >0.809). Inter-rater reliability was moderate to good for the UG (ICC 0.693 (95 % CI 0.580 to 0.788)) and good for the Dr G application (ICC 0.708 (95 % CI 0.597 to 0.799)).
Conclusions: Moderate to high intra and inter-rater reliability of joint position and passive 1st MTPJ motion can be achieved with traditional and smartphone-based goniometric measurement. The Dr G application may provide a slightly higher reliability, but devices should not be used inter-changeably as significant variation in measurement between devices may occur.