Feasibility of diffusion-weighted imaging with DWIBS in staging Hodgkin lymphoma in pediatric patients: comparison with PET/CT.

Journal: Magma (New York, N.Y.)
Published:
Abstract

Objective: The aim of the study was to evaluate feasibility of diffusion-weighted whole-body imaging with background body signal suppression (DWIBS) method in diagnosing Hodgkin lymphoma in pediatric patients and to compare it with 18F-FDG PET/CT as a gold standard.

Methods: Eleven patients (median age 14) with newly diagnosed Hodgkin lymphoma were examined with 18F-FDG PET/CT and MRI including whole-body DWIBS sequence (b = 0, 800 s/mm2), before the oncologic treatment. About 26 locations of lymphatic tissues were evaluated visually and quantitatively using ADCmean (DWIBS) and SUVmax (18F-FDG PET/CT), respectively.

Results: All affected lymph node regions (n = 134) diagnosed in 18F-FDG PET/CT were found with DWIBS, presenting decreased diffusion. Significant correlation was found between ADC and SUV values (R2 = - 0.37; p = 0.0001). Nevertheless, additional 33 regions were recognized only by DWIBS. They were significantly smaller than regions diagnosed by both methods.

Conclusions: Agreement between DWIBS and 18F-FDG PET/CT for detection and staging of malignant lymphoma is high. DWIBS can be used for the evaluation of pediatric Hodgkin lymphoma.

Authors
Dobromila Baranska, Katarzyna Matera, Michal Podgorski, Magdalena Gorska Chrzastek, Karolina Krajewska, Joanna Trelinska, Piotr Grzelak
Relevant Conditions

Hodgkin Lymphoma