Comparison of Airtraq™, McCoy™ and Macintosh laryngoscopes for endotracheal intubation in patients with cervical spine immobilisation: A randomised clinical trial.
Objective: The study aimed at comparing the performance of the novel optical Airtraq™ laryngoscope with the McCoy™ and conventional Macintosh laryngoscopes for ease of endotracheal intubation in patients with neck immobilisation using manual inline axial cervical spine stabilisation (MIAS) technique.
Methods: Ninety consenting American Society of Anaesthesiologist's physical status I-II patients, aged 18-60 years, scheduled for various surgeries requiring tracheal intubation were randomly assigned into three groups of thirty each to undergo intubation with Macintosh, Airtraq™, or McCoy™ laryngoscope with neck immobilisation by MIAS technique. The ease of intubation based on Intubation difficulty scale (IDS) score, Cormack-Lehane grade of glottic view, optimisation manoeuvres and impact on haemodynamic parameters were recorded. Statistical analysis was performed with ANOVA and Bonferroni correction for post hoc tests.
Results: All patients in three groups had a comparable demographic profile and were successfully intubated. The Airtraq™ laryngoscope significantly reduced the IDS (mean - 0.43 ± 0.81) as compared with both McCoy™ (mean - 1.63 ± 1.49, P = 0.001) and Macintosh laryngoscope (mean -2.23 ± 1.92, P < 0.001) and improved the Cormack-Lehane glottic view (77% grade 1 view and no patients with grade 3 or 4 view). There were less haemodynamic variations during laryngoscopy with the Airtraq™ compared to the Macintosh laryngoscope, but there was not between the Airtraq™ and McCoy™ laryngoscope groups.
Conclusions: In patients undergoing endotracheal intubation with cervical immobilisation, Airtraq™ laryngoscope was superior to the McCoy™ and Macintosh laryngoscopes, with greater ease of intubation and lower impact on haemodynamic variables.