Treatment of a Dialysate Leak by Simultaneous Catheter Removal and Replacement in a Patient Undergoing Continuous Ambulatory Peritoneal Dialysis.

Journal: Advances In Peritoneal Dialysis. Conference On Peritoneal Dialysis
Published:
Abstract

Continuous ambulatory peritoneal dialysis (PD) is one of the treatment methods used for end-stage renal failure. When mechanical complications occur with this treatment method, methods such as tomographic peritoneography, abdominal scintigraphy, and magnetic resonance peritoneography are used to uncover the problem. Here, we report the detection by tomographic peritoneography of a subcutaneous dialysate leak in a patient undergoing PD. The PD catheter was subsequently removed, and a new catheter was inserted. The patient then restarted continuous ambulatory PD without any problem.

Authors
Erim Gülcan, Muhammet Kalay, Özlem Kabak, Süreyya Özbay