Spinal dural closure without suture: Minimizing the risk of CSF leakage with a flat non-penetrating titanium U-clip.

Journal: Neurocirugia (English Edition)
Published:
Abstract

Background: The classic surgical spinal dural closure technique in surgery on intradural lesions is performed with continuous suture or loose stitches using 4-0 to 6-0 polypropylene monofilament or nylon suture. Dural closure with suture causes irritant damage to the dural/arachnoid interface. The penetrating suture causes new dural holes. Even the needle of the suture can cause harm to the patient and the surgeon. For these reasons, other non-penetrating techniques for dural closure have been sought.

Objective: The purpose of this review was to show the efficacy of using the titanium clip (U-clip) (Ligaclip-MCA of Ethicon Endo-Surgery, LLC, Medical GmbH, Norderstedt, Germany) with a flat internal surface in spinal neurosurgical procedures, and to evaluate the effects of its use on post-operative magnetic resonance imaging (MRI).

Methods: We performed a retrospective analysis of a cohort of 50 consecutive patients who underwent intradural spinal surgeries for intradural spinal lesions in the neurosurgery department of our institution between 2013 and 2018.

Results: The mean follow-up period was 27 months. No patient developed a post-operative cerebrospinal fluid (CSF) dural-cutaneous fistula. CSF leakage was not observed in the control MRIs at 6 weeks.

Conclusions: We describe, for the first time, the use of this type of U-clip with a flat inner side. The non-penetrating titanium U-clip facilitates effective and rapid dural closure at all spinal levels due to its flat internal face when closed. The U-clips did not cause significant artefacts or distortions on the magnetic resonance imaging.

Authors
Francisco Marin Laut, Efraim Gómez Cárdenas, Jesús Dormido, Nicolás Molina, Jose López
Relevant Conditions

Spinal Tumor, Laminectomy