Hybrid Ventricular Tachycardia Ablation after Failed Percutaneous Endocardial and Epicardial Ablation.
Background: Recurrent ventricular tachycardia (VT) after percutaneous ablation is associated with a high morbidity and mortality. We assessed the feasibility of open chest extracorporeal circulation (ECC)-supported 3D multielectrode mapping and targeted VT substrate ablation in patients with previously failed percutaneous endocardial and epicardial VT ablations.
Methods: In patients with previously failed percutaneous endocardial and epicardial VT ablations and a high risk of hemodynamic collapse during the procedure, open chest ECC-supported mapping and ablation were performed in a hybrid EP lab setting. Electro-anatomic maps (3D) were acquired during sinus rhythm and VT using a multielectrode mapping catheter (HD grid; Abbott or Pentaray, Biosense Webster). Irrigated radiofrequency ablations of all inducible VT were performed with a contact force ablation catheter.
Results: Hybrid VT ablation was performed in 5 patients with structural heart disease (i.e., 3 with previous old myocardial infarction and 2 with nonischemic cardiomy-opathy) and recurrent VT. Acute procedural success was achieved in all patients. Four patients were successfully weaned off the ECC. In 1 patient with a severely reduced LVEF (16%), damage to the venous graft occurred after sternotomy and that patient died after 1 month. Four patients (80%) remained VT free after a median follow-up of 6 (IQR 4-10) months.
Conclusions: In high-risk patients with previously failed percutaneous endocardial and epicardial VT ablations, open chest ECC-supported multielectrode epicardial mapping revealed a VT substrate in all of the patients, and targeted epicardial ablation abolished VT substrate in these patients.