Diagnostic yield of early repeat colonoscopy after suboptimal bowel preparation in a fecal immunochemical test-based screening program.

Journal: Endoscopy
Published:
Abstract

Background: Current guidelines regarding surveillance after screening colonoscopy assume adequate bowel preparation. However, follow-up intervals after suboptimal cleansing are highly heterogeneous. We aimed to determine the diagnostic yield of early repeat colonoscopy in patients with suboptimal bowel preparation in fecal immunochemical test (FIT)-based screening colonoscopy.

Methods: An observational study including patients who underwent colonoscopy with suboptimal bowel preparation after positive FIT screening and then repeat colonoscopy within 1 year. Suboptimal preparation was defined as a Boston Bowel Preparation Scale (BBPS) score of 1 in any segment. Patients with a BBPS score of 0 in any segment or incomplete examination were excluded. The adenoma detection rate (ADR), advanced ADR (AADR), and colorectal cancer rate were calculated for the index and repeat colonoscopies.

Results: Of the 2474 patients with FIT-positive colonoscopy at our center during this period, 314 (12.7 %) had suboptimal preparation. Of the 259 (82.5 %) patients who underwent repeat colonoscopy, suboptimal cleansing persisted in 22 (9 %). On repeat colonoscopy, the ADR was 38.7 % (95 %CI 32.6 % to 44.8 %) and the AADR was 14.9 % (95 %CI 10.5 % to 19.4 %). The per-adenoma miss rate was 27.7 % (95 %CI 24.0 % to 31.6 %), and the per-advanced adenoma miss rate was 17.6 % (95 %CI 13.3 % to 22.7 %). After repeat colonoscopy, the post-polypectomy surveillance recommendation changed from 10 to 3 years in 14.7 % of the patients with previous 10-year surveillance recommendation.

Conclusions: Patients with suboptimal bowel preparation on FIT-positive colonoscopy present a high rate of advanced adenomas in repeat colonoscopy, with major changes in post-polypectomy surveillance recommendations.