Clinical COVID-19 diagnostic methods: Comparison of reverse transcription loop-mediated isothermal amplification (RT-LAMP) and quantitative RT-PCR (qRT-PCR).

Journal: Journal Of Clinical Virology : The Official Publication Of The Pan American Society For Clinical Virology
Published:
Abstract

Background: The coronavirus disease 2019 (COVID-19) pandemic is a major public health concern. Accurate and rapid diagnosis of COVID-19 is critical for disease control. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is a nucleic acid amplification assay similar to reverse transcription-polymerase chain reaction (RT-PCR), the former being a simple, low cost, and rapid method. Objectives: This study aimed to compare the RT-LAMP assay with RT-PCR using the Loopamp™ SARS-CoV-2 Detection Kit. Study

Design: One hundred and fifty-one nasopharyngeal swab and 88 sputum samples obtained from individuals with suspected or confirmed COVID-19 were examined.

Results: RT-LAMP had high specificity (98.5 % (95 % CI: 96.9-100 %)), sensitivity (87.0 % (95 % CI: 82.8-91.3 %)), positive predictive value (97.9 % (95 % CI: 96.1-99.7 %)), negative predictive value (90.2 % (95 % CI: 86.4-94.0 %)), and concordance rate (93.3 % (95 % CI: 90.1-96.5 %)). Nasopharyngeal and sputum samples positive in RT-LAMP contained as few as 10.2 and 23.4 copies per 10 μL, respectively. RT-LAMP showed similar performance to RT-PCR for samples with cycle threshold value below 36.

Conclusions: These results indicate that RT-LAMP is a highly reliable and at least equivalent to RT-PCR in utility, and potentially applicable in settings that are more diverse as a point-of-care tool.

Authors
Heita Kitajima, Yoshitaka Tamura, Hiroko Yoshida, Hitomi Kinoshita, Hiroki Katsuta, Chika Matsui, Akane Matsushita, Tsuyoshi Arai, Shoji Hashimoto, Atsuhiko Iuchi, Tomonori Hirashima, Hiroshi Morishita, Hiroto Matsuoka, Toshio Tanaka, Takayuki Nagai