Dosimetric predictors of local control and complications in gynecologic transperineal implant patients: The medical college of wisconsin experience.
Purpose: Investigate the relationship between dosimetric parameters with local control (LC) and complications following transperineal high-dose rate (HDR) interstitial brachytherapy (ISBT) for gynecologic (GYN) malignancies. Methods and materials: Between 2001 and 2016, 59 patients were treated for primary or recurrent GYN malignancies. Most patients received external beam irradiation, followed by transperineal ISBT via the Syed-Neblett applicator set with CT-based planning. Treatment plans were retrospectively reviewed to evaluate for an association among LC or toxicity with the equivalent dose at 2 Gy per fraction (EQD2) for the clinical target volume (CTV), 0.1 cc (D0.1cc), and 2 cc (D2cc) volumes of the organs at risk (OAR), low/high dose volumes for the OAR and CTV, and ratio of dose at the core vs. the implant periphery.
Results: The median follow-up among survivors was 24 months. 34% of patients had a component of local failure and in 12%, this was isolated. Late grade 3 (G3) toxicity occurred in 15% of patients. There were no G4-5 toxicities. Rectal D0.1cc > 75 Gy trended toward significance in predicting the development of non-fistula late G2-3 rectal complications. Bladder D0.1cc > 94 Gy significantly predicted for the development of late G2-3 vesicovaginal fistula formation. The ratio of the total dose at the vaginal surface to the needle periphery above 121% trended in predicting for any complication or fistula formation.
Conclusions: HDR ISBT combined with EBRT achieved LC in 66% of patients with advanced or recurrent GYN cancers. Rectal and bladder D0.1cc doses may be predictive of complications as may the ratio of the implant dose at the core vs. periphery.