Nitric oxide and long-term outcomes after kidney transplantation: Results of the TransplantLines cohort study.
Impaired endogenous nitric oxide (NO) production may contribute to graft failure and premature mortality in kidney transplant recipients (KTR). We investigated potential associations of 24-h urinary NOx (NO3- + NO2-) excretion (uNOx) with long-term outcomes. uNOx was determined by HPLC and GC-MS in 698 KTR and in 132 kidney donors before and after donation. Additionally, we measured urinary nitroso species (RXNO) by gas-phase chemiluminescence. Median uNOx was lower in KTR compared to kidney donors (688 [393-1076] vs. 1301 [868-1863] before donation and 1312 [982-1853] μmol/24 h after donation, P < 0.001). During median follow-up of 5.4 [4.8-6.1] years, 150 KTR died (61 due to cardiovascular disease) and 83 experienced graft failure. uNOx was inversely associated with all-cause mortality (HR per doubling of uNOx: 0.84 [95% CI 0.75-0.93], P < 0.001) and cardiovascular mortality (HR 0.78 [95% CI 0.67-0.92], P = 0.002). The association of uNOx with graft failure was lost when adjusted for renal function (HR per doubling of uNOx: 0.89 [95% CI 0.76-1.05], P = 0.17). There were no significant associations of urinary RXNO with outcomes. Our study suggests that KTR have lower NO production than healthy subjects and that lower uNOx is associated with a higher risk of all-cause and cardiovascular mortality.