Quantitative single photon emission computed tomography derived standardized uptake values on 99mTc-PYP scan in patients with suspected ATTR cardiac amyloidosis.

Journal: Journal Of Nuclear Cardiology : Official Publication Of The American Society Of Nuclear Cardiology
Published:
Abstract

Technetium-99 pyrophosphate scintigraphy (99mTc-PYP) provides qualitative and semiquantitative diagnosis of ATTR cardiac amyloidosis (ATTR-CA) using the Perugini scoring system and heart/contralateral heart ratio (H/CL) on planar imaging. Standardized uptake values (SUV) with quantitative single photon emission computed tomography (xSPECT/CT) can offer superior diagnostic accuracy and quantification through precise myocardial contouring that enhances assessment of ATTR-CA burden. We examined the correlation of xSPECT/CT SUVs with Perugini score and H/CL ratio. We also assessed SUV correlation with cardiac magnetic resonance (CMR), echocardiographic, and baseline clinical characteristics. Retrospective review of 78 patients with suspected ATTR-CA that underwent 99mTc-PYP scintigraphy with xSPECT/CT. Patients were grouped off Perugini score (Grade 0-1 and Grade 2-3), H/CL ratio (≥ 1.5 and < 1.5). Two cohorts were also created: myocardium SUVmax > 1.88 and ≤ 1.88 at 1-hour based off an AUC curve with 1.88 showing the greatest sensitivity and specificity. Cardiac SUV retention index was calculated as [SUVmax myocardium/SUVmax vertebrae] × SUVmax paraspinal muscle. Primary outcome was myocardium SUVmax at 1-hour correlation with Perugini grades, H/CL ratio, CMR, and echocardiographic data. Higher Perugini Grades corresponded with higher myocardium SUVmax values, especially when comparing Perugini Grade 3 to Grade 2 and 1 (3.03 ± 2.1 vs 0.59 ± 0.97 and 0.09 ± 0.2, P < 0.001). Additionally, patients with H/CL ≥ 1.5 had significantly higher myocardium SUVmax compared to patients with H/CL ≤ 1.5 (2.92 ± 2.18 vs 0.35 ± 0.60, P < 0.01). Myocardium SUVmax at 1-hour strongly correlated with ECV (r = 0.91, P = 0.001), pre-contrast T1 map values (r = 0.66, P = 0.037), and left ventricle mass index (r = 0.80, P = 0.002) on CMR. SUVs derived from 99mTc-PYP scintigraphy with xSPECT/CT provides a discriminatory and quantitative method to diagnose and assess ATTR-CA burden. These findings strongly correlate with CMR.

Authors
Juan Avalon, Jacob Fuqua, Seth Deskins, Tyler Miller, Justin Conte, Daniel Martin, Gary Marano, Naveena Yanamala, James Mills, Christopher Bianco, Brijesh Patel, Karthik Seetharam, Raymond Raylman, Partho Sengupta, Yasmin Hamirani