Treatment using balloon catheterization of pulmonary valve stenosis
From October 84 to September 88 we performed pulmonary valvuloplasty with balloon catheter (PVBC) in 90 patients (pt) with pulmonary valve stenosis (PVS). The patients were divided in 3 groups (Gr) by their ages: group I (Gr. I) 7 pt (8%) aged 4 days to 11 months, Gr. II 66 pt (73%) aged 1 year to 12 years and Gr. III 17 pt aged 13 to 34 years. This study consists of clinical and echocardiographic evaluation adopting the following parameters of indication: a) transvalvar pulmonary gradient (G); b) absence of dysplasia or hypoplasia of the pulmonary annulus. There were associated lesions which were found in each group: Gr. I atrial septal defect (ASD) in 2 pt and tricuspid insufficiency (TI) in 1 pt, in Gr. II supra valvar stenosis (SVS) in 1 pt and patent arterial ductus (PAD) in 1 pt and in the Gr. III (ASD) in 1 pt. The results after pulmonary valvuloplasty with balloon catheter (PVBC) were: (Gr.I) in 5 pt the G were reduced below 50 mmHg and the average of right ventricular systolic pressure (RVSP) changed from 92 to 62 mmHg and the average of G from 76 to 44 mmHg. One of these pt was submitted to surgery 1 month after the procedure and 2 developed restenosis in 2 and 3 years respectively, being submitted to another dilatation with good results. The 2 pt in which the procedure was not effective were submitted to surgery. In the second group the PVBC was effective in 61 pt (92%) showing the RVSP changed from 118 to 64 mmHg and G changed from 86 to 23 mmHg.(ABSTRACT TRUNCATED AT 250 WORDS)