Subcutaneous versus transvenous implantable cardioverter defibrillator in hypertrophic cardiomyopathy: a systematic review and meta-analysis.

Journal: Cardiovascular Diagnosis And Therapy
Published:
Abstract

A subcutaneous implantable cardioverter-defibrillator (S-ICD) is an alternative to a transvenous implantable cardio defibrillator (TV-ICD). An S-ICD reduces the risk of transvenous lead placement. However, further research is required to determine how S-ICDs affect patients with hypertrophic cardiomyopathy (HCM). In this study, we investigated the comparative efficacy and safety of S-ICDs versus TV-ICDs in HCM. On December 6th, 2023, we performed a comprehensive search of the PubMed, Embase, Scopus, and Cochrane databases to identify randomized clinical trials (RCTs) and observational studies comparing S-ICDs with TV-ICDs in HCM patients published from 2004 until 2023. No language restrictions were applied. The primary outcome was appropriate shocks (AS), with inappropriate shocks (IAS), and device-related complications considered as secondary outcomes. Odds ratios (ORs) and 95% confidence intervals (CIs) were pooled using a random effects model. The ROBINS-I tool was used to assess the risk of bias of the studies. The search yielded 1,114 records. Seven studies comprising 4,347 HCM patients were included, of whom 3,325 (76.0%) had TV-ICDs, and 1,022 (22.6%) had S-ICDs. There were 2,564 males (58.9%). The age range was from 39.1 to 49.4 years. Compared with the TV-ICD group, the S-ICD cohort had a significantly lower incidence of device-related complications (OR 0.52; 95% CI: 0.30-0.89; P=0.02; I2=4%). Contrastingly, there were no statistically significant differences in the occurrences of AS (OR 0.49; 95% CI: 0.22-1.08; P=0.08; I2=75%) and IAS (OR 1.03; 95% CI: 0.57-1.84; P=0.93; I2=65%) between the two device modalities. In the analysis of the overall risk of bias in the studies, we found 42% of them with several, 28% with moderate, and 14% with low risk of bias. In HCM patients, S-ICDs were associated with a lower incidence of device-associated problems than TV-ICDs. AS and IAS incidence rates were similar between groups. These findings may assist clinicians in determining the most suitable device for treating patients with HCM.

Authors
Antônio Da Silva Menezes Júnior, Izadora Oliveira, André De Sousa, Ricardo Paro Piai, Vinícius Martins Oliveira