Cardiac tamponade due to right coronary artery perforation following pacemaker implantation: a case report.

Journal: European Heart Journal. Case Reports
Published:
Abstract

Cardiac tamponade due to perforation of a cardiac chamber is a rare complication occurring in only 0.3% of patients undergoing permanent pacemaker (PM) implantation. Notably, perforation of the right coronary artery (RCA) following permanent PM implantation has only been reported twice in the literature. We report a rare case of RCA perforation leading to life-threatening cardiac tamponade with symptom onset 4 days after PM implantation. A 75-year-old woman underwent permanent PM implantation without any difficulties in placing pacemaker leads and with good thresholds. Four days later, the patient was readmitted in a state of shock due to cardiac tamponade. A blood gas analysis on the bloody pericardial effusion raised suspicion of ongoing arterial bleeding. A CT scan ruled out aortic dissection; instead, the source of bleeding was identified as a perforation in the RCA, which was managed surgically. This case highlights the necessity of coronary artery perforation being among the differential diagnoses of cardiac tamponade after PM implantation, and it stresses the usefulness of performing a blood gas analysis on the bloody pericardial effusion.

Authors
Zakaria Alaoui Ismaili, Anika Klein, Jacob Moeller, Tommi Bo Lindhardt, Christian Hassager