His bundle pacing combined with atrioventricular node ablation for atrial fibrillation: a systematic review and meta-analysis.
His bundle pacing (HBP) could replace failed biventricular pacing (BVP) in guidelines (IIa Indication), but the high capture thresholds and backup lead pacing requirements limit its development. We assessed the efficacy and safety of HBP combined with atrioventricular node ablation (AVNA) for atrial fibrillation (AF) and compared with BVP and left bundle branch pacing (LBBP). We reviewed PubMed, Embase, Web of Science, and Cochrane Library databases on left ventricular ejection fraction (LVEF), New York Heart Association (NYHA) score, QRS duration (QRSd), and pacing threshold. Thirteen studies included 1115 patients (639 with HBP, 338 with BVP, and 221 with LBBP). Compared with baseline, HBP improved LVEF (mean difference [MD]: 9.24 [6.10, 12.37]; p < 0.01), reduced NYHA score (MD: -1.12 [-1.34, -0.91]; p < 0.01), increased QRSd (MD: 10.08 [4.45, 15.70]; p < 0.01), and rose pacing threshold (MD: 0.16 [0.05, 0.26]; p < 0.01). HBP had comparable efficacy to BVP and LBBP and lower QRSd (p < 0.05). HBP had a lower success rate (85.97%) and more complications (16.1%). HBP combined with AVNA is effective for AF, despite having a lower success rate and more complications. Further trials are required to determine whether HBP is superior to BVP and LBBP.