Application value of one-hour post-load glucose ≥8.6 mmol/L during oral glucose tolerance test in detecting prediabetes
Objective: To assess the application value of one-hour post-load glucose (1hPG) for detecting prediabetes among individuals with high risk of type 2 diabetes mellitus (T2DM).
Methods: The study was conducted between August 2023 and January 2024, and individuals with a high risk of T2DM were invited to receive an oral glucose tolerance test (OGTT), structural questionnaires, physical measurements, and other biochemical examinations. The fasting, one-, and two-hour glucose and insulin were tested. According to the 1hPG cut point on hyperglycemia suggested by International Diabetes Federation (IDF), normal glucose tolerance (NGT) and prediabetes were further divided into two subgroups, respectively, i.e., NGT with 1hPG<8.6 mmol/L (NGT-1hPG-normal), NGT with 1hPG≥8.6 mmol/L (NGT-1hPG-high), prediabetes with 1hPG<8.6 mmol/L (PDM-1hPG-normal), and prediabetes with 1hPG≥8.6 mmol/L (PDM-1hPG-high). The insulin release curve was drawn by the groups as above. Insulin resistance was evaluated by homeostasis model assessment for insulin resistance (HOMA-IR), and β-cell secretory function was evaluated by homeostasis model assessment for β cell function (HOMA-β)/HOMA-IR. Spearman rank correlation analysis was used to calculate the correlation coefficients among 1hPG, 2hPG and HOMA indices, and Steiger's Z test was used to compare the difference between two correlation coefficients. Receiver operating characteristics (ROC) curves and area under the curve (AUC) were used to assess the accuracy of 1hPG for detecting prediabetes.
Results: A total of 2 469 subjects consisting of 1 485 men (60.1%) and 984 (39.9%) women, with a mean age of (45.76±6.20) years, of which 1 844 (74.7%) had 1hPG≥8.6 mmol/L. The prevalence of 1hPG≥8.6 mmol/L was 46.8%, 93.0% and 99.8% in individuals with NGT, prediabetes and newly diagnosed T2DM, respectively (χ2=763.78, P<0.001). The insulin release curve showed that insulin secretion increased rapidly in subjects with NGT-1hPG-high, and peaked at one hour, then decreased rapidly, with a significantly higher level of one- and two-hour insulin than those with NGT-1hPG-normal (P<0.001). Compared to individuals with NGT-1hPG-normal, the counterparts with NGT-1hPG-high exhibited higher HOMA-IR and lower adjusted HOMA-β (P<0.001). Spearman rank correlation analysis showed that the correlation coefficient of 1hPG with HOMA-IR was similar to the correlation coefficient of 2hPG with HOMA-IR (0.493 vs. 0.480, P=0.550), while the correlation of 1hPG with adjusted HOMA-β was significantly stronger than that of 2hPG (-0.692 vs. -0.587, P<0.001). Excluding patients with T2DM, according to the cut point recommended by IDF, the AUC of 1hPG≥8.6 mmol/L for detecting prediabetes was 0.731 (95%CI: 0.714-0.748), and the sensitivity and specificity were 0.930 and 0.532, respectively, with the kappa value of 0.45.
Conclusion: 1hPG is closely related to insulin resistance and islet function, and there's substantial value for individuals with a high risk of T2DM to detect prediabetes by using the 1hPG cut points recommended by IDF.