Detection of a local slow potential preceding the surface QRS complex during non-preexcited impulse propagation--a phenomenon reflecting anterograde concealed conduction through the accessory pathway?

Journal: Japanese Circulation Journal
Published:
Abstract

A case of Wolff-Parkinson-White (WPW) syndrome with several interesting electrophysiologic findings is presented. Although manifest preexcitation had not been documented in clinical routine check-ups for the 2 years before the ablation session, an intermittent preexcitation emerged after an initial unsuccessful radiofrequency current delivery directed at the subvalvular mitral annulus 1 cm distal from the subsequent successful ablation site. During intermittent manifestation of preexcitation, the following observations were made: (1) during manifest preexcitation, a possible Kent potential was recorded at the successful ablation site; (2) during non-preexcited impulse propagation, a local slow potential preceding the QRS complex (pre-QRS potential) was clearly observed at the same site; (3) the pre-QRS potential disappeared during orthodromic atrioventricular reciprocating tachycardia, spontaneous atrial premature contraction and after the subsequent successful ablation; and (4) when the pre-QRS potential was obvious, a small change in QRS morphology of the body-surface ECG was appreciable, compared with that during beats of negative pre-QRS potential. A comparable preceding component was also detected in a signal-averaged ECG. It is considered that the pre-QRS potential might be related to the anterograde concealed conduction through the accessory pathway.

Authors
Y Kobayashi, Y Miyauchi, N Kawaguchi, K Ohmura, H Saitoh, T Ino, H Atarashi, T Katoh, H Kishida, H Hayakawa