Evaluation of global and regional left ventricular function obtained by quantitative gated SPECT using 99mTc-tetrofosmin for left ventricular dysfunction.

Journal: Internal Medicine (Tokyo, Japan)
Published:
Abstract

Objective: The quantitative gated SPECT (QGS) software is able to calculate LV volumes and visualize LV wall motion and perfusion throughout the cardiac cycle using an automatic edge detection algorithm of the left ventricle. We evaluated the reliability of global and regional LV function assessment derived from QGS by comparing it with the results from left ventriculo-cineangiography (LVG).

Methods: In 20 patients with left ventricular dysfunction who underwent ECG gated 99mTc-tetrofosmin SPECT, the end-diastolic volume (EDV), end-systolic volume (ESV) and ejection fraction (LVEF) were calculated. The QGS-assessed regional wall motion was determined using the cinematic display.

Results: QGS-derived EDV, ESV and LVEF correlated well with those by LVG (p<0.001 for each). There was a good correlation between wall motion score (WMS) derived from the QGS and the LVG (r=0.40, p<0.05). In some patients with extensive myocardial infarction, there was a discrepancy in the regional wall motion results between QGS and LVG.

Conclusions: The ECG-gated SPECT using QGS is useful to evaluate global and regional LV functions in left ventricular dysfunction.