Follow-up on MEWDS by fundus perimetry and multifocal ERG with the SLO

Journal: Der Ophthalmologe : Zeitschrift Der Deutschen Ophthalmologischen Gesellschaft
Published:
Abstract

Background: Most conventional techniques for examination such as perimetry or ERG may not be sensitive enough to detect functional alterations due to MEWDS precisely. We report on a follow-up performed by fundus perimetry and the new technique of multifocal ERG using the scanning laser ophthalmoscope.

Methods: A 24-year-old female patient (VA 0.2/0.8) was followed up for 7 weeks with these techniques as well as Octopus perimetry, fluorescence angiography, Ganzfeld ERG and biomicroscopy. Multifocal ERG stimulation (mfERG, Retiscan) was performed with the SLO.

Results: Visual acuity improved from 0.2 to 0.8 and the central relative scotoma disappeared while a relevant increase of P1-wave amplitudes in mfERG could be observed.

Conclusions: Combining objective measurements from the fundus controlled SLO-mfERG and results from fundus perimetry enable good correlation of morphology and results, even for minor alterations of the macula only accessible by few established clinical examinations.

Authors
S Bültmann, M Martin, K Rohrschneider
Relevant Conditions

Uveitis