Comparing multifocal VEP and standard automated perimetry in high-risk ocular hypertension and early glaucoma.

Journal: Investigative Ophthalmology & Visual Science
Published:
Abstract

Objective: To compare the diagnostic performance of multifocal visual evoked potential (mfVEP) and standard automated perimetry (SAP), in eyes with high-risk ocular hypertension or early glaucoma.

Methods: Both eyes of 185 individuals with high-risk ocular hypertension or early glaucoma were evaluated. Subjects ranged in age from 37 to 87 (mean +/- SD: 61 +/- 11 years). Pattern-reversal mfVEPs were obtained by using VERIS (Electro-Diagnostic Imaging, San Mateo, CA) with a four-electrode array and were analyzed with custom software. SAP visual fields (SITA-standard; Carl Zeiss Meditec, Inc., Dublin, CA) were obtained within 22.3 +/- 27.0 days of the mfVEP. Stereo disc photographs and Heidelberg Retina Tomograph (HRT) images were obtained during one visit, which was within 24.8 +/- 50.4 days of the mfVEP and 33.1 +/- 62.9 days of the SAP visual field. Abnormalities on the mfVEP were defined by using a variety of cluster criteria: SAP with pattern standard deviation (PSD) P

Results: results. Disc photographs from 50% of eyes were graded GON. Both eyes were graded GON in 71 (38%) of the 185 subjects. Exactly half as many eyes were abnormal by HRT MRA. The average SAP mean deviation (MD) was +0.3 +/- 2.1 dB; average PSD was 2.3 +/- 1.9 dB. By OHTS criteria, 83 (22%) of the 370 eyes had an abnormal SAP. Depending on the cluster criterion used, the proportion of eyes with an abnormal SAP ranged from 8% to 26% and with an abnormal mfVEP, from 14% to 45%. A criterion with an estimated specificity in normal subjects of 91% resulted in 102 (28%) eyes with an abnormal mfVEP. For criteria with estimated specificities of 95% and 99%, respectively, 88 (24%) eyes and 52 (14%) eyes had an abnormal mfVEP. Agreement between SAP and mfVEP ranged from 75% to 81%. The sensitivity of SAP-OHTS to detect GON (using the disc photograph as diagnostic standard) was 29%, whereas specificity was 84%. Sensitivity of the mfVEP to detect GON, for cluster criteria with disc structure specificity between 84% and 87%, ranged from 28% to 32%. When the HRT MRA was used as the diagnostic standard, sensitivities of both functional tests to detect GON increased to 42%.

Conclusions: The diagnostic performance of mfVEP was similar to that of SAP. However, the two modalities agreed in only approximately 80% of eyes, suggesting that they may detect slightly different functional deficits.

Authors
Brad Fortune, Shaban Demirel, Xian Zhang, Donald Hood, Emily Patterson, Annisa Jamil, Steven Mansberger, George Cioffi, Chris Johnson