Fluorescein filling defects and quantitative morphologic analysis of the optic nerve head in glaucoma.
Objective: To evaluate absolute filling defects of the optic nerve head in normal tension glaucoma (NTG) and primary open-angle glaucoma (POAG) and to compare the filling defects with topographic analysis of the optic disc.
Methods: Twenty-five patients with NTG, 25 patients with POAG, and 25 age-matched controls were included. Fluorescein angiograms were performed by means of a scanning laser ophthalmoscope. The extent of absolute filling defects of the optic nerve head was assessed using digital image analysis of early-phase angiograms. Topographic measurements of the optic disc were acquired using the Heidelberg Retina Tomograph II.
Results: Absolute filling defects were significantly larger (P =.001) and were seen more often (P<.001) in patients with NTG (n = 18) and POAG (n = 19) compared with controls (n = 3). Rim area (P =.006), rim volume (P =.007), cup-disc area ratio (P =.008), linear cup-disc ratio (P =.005), maximum cup depth (P =.002), cup shape measure (P =.03), and nerve fiber layer thickness (P =.008) and cross-sectional area (P =.006) were significantly different between patients with glaucoma and controls. Absolute filling defects were significantly correlated with cup area (r = 0.31; P =.007), rim area (r = -0.38; P<.001), rim volume (r = -0.35; P =.002), cup-disc area ratio (r = 0.49; P<.001), linear cup-disc ratio (r = 0.48; P<.001), cup shape measure (r = 0.27; P =.02), and nerve fiber layer thickness (r = -0.33; P =.004) and cross-sectional area (r = -0.30; P =.009).
Conclusions: Fluorescein filling defects of the optic disc are present in NTG and POAG. The extent of these filling defects is correlated with the morphologic disc damage.