Evaluation of amplicor chlamydia PCR and LCX chlamydia LCR to detect Chlamydia trachomatis in synovial fluid.

Journal: Clinical And Experimental Rheumatology
Published:
Abstract

Objective: PCR has been successfully used in research for the detection of C. trachomatis DNA in synovial samples. However, each research laboratory has developed its own PCR, making inter-laboratory comparisons difficult. To allow for standardization we evaluated two commercially available amplification systems originally designed for the examination of urogenital samples (Roche Amplicor Chlamydia PCR and Abbott LCX Chlamydia LCR), using them to analyse spiked and clinical synovial fluid (SF) samples from reactive arthritis (ReA), undifferentiated arthritis (UA), and rheumatoid arthritis (RA) patients. We compared their sensitivity in assays of clinical SF samples with our in-house developed C. trachomatis specific nested PCR.

Methods: SF was spiked with purified C. trachomatis elementary bodies (EB) and analyzed by the commercial assays. Clinical SF samplesfrom ReA (n=21), UA (n=79) and RA (n=50) patients were examined by the two commercial assays and our in-house PCR.

Results: Using SF samples spiked with defined numbers of C. trachomatis EB, the sensitivity of the commercial tests was high and similar to published PCR sensitivity. In clinical SF specimens the commercial assays was also able to detect CT; however, the in-house PCR was more sensitive. Out of 10 PCR-positive SF samples Amplicor tested positive in only 4/10 and LCX in only 3/10. The in-house PCR detected chlamydial DNA in synovialfluidfrom 5/21 ReA (24%), 5/79 UA (6%) and in none of the 50 RA patients.

Conclusions: Commercial amplification assays allow the detection of C. trachomatis in clinical specimens, although with a lower sensitivity than optimized PCR. Potential explanations are discussed.

Authors
J Kuipers, J Andresen, L Köhler, S Schnarr, N Putschky, H Zeidler, J Wollenhaupt